Search results for "Radiation field"

showing 9 items of 9 documents

Quantum Stochastic Resonance in a Micromaser

1998

We demonstrate that quantum stochastic resonance allows for the noise-controlled synchronization of quantum jumps between the metastable states of the quantized radiation field in a micromaser. Under readily accessible experimental conditions optimal synchronization is achieved at a finite temperature $T\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}500\mathrm{mK}$ of the environment.

PhysicsMetastabilityQuantum mechanicsRadiation fieldQuantum electrodynamicsSynchronization (computer science)General Physics and AstronomyStochastic resonance (sensory neurobiology)QuantumImaging phantomPhysical Review Letters
researchProduct

Quantum beats from dressed three-level atoms

1983

Abstract By extending a previously developed unitary transformation technique to dress three-level atoms by a strong driving radiation field, we show that quantum beats can be induced by the presence of the driving field also when the decay channels lead from a singlet to a doublet of lower energy. A qualitative explanation of this effect is presented, which is based on the quantum theory of measurement.

PhysicsField (physics)Radiation fieldUnitary transformationAtomic and Molecular Physics and OpticsThree levelLower energyElectronic Optical and Magnetic MaterialsQuantum beatsQuantum mechanicsSinglet stateElectrical and Electronic EngineeringPhysical and Theoretical ChemistryAtomic physicsOptics Communications
researchProduct

The significance of a uniform definition of pathological lymph nodes in Hodgkin lymphoma: impact of different thresholds for positive lymph nodes in …

2007

Abstract Background and Purpose The most commonly used approach for the assessment for differentiating malignant versus reactive lymph nodes is the measurement of the cross-section diameter of the lymph nodes in the transversal CT-planes. The intention of this article is to assess the impact of varying definitions of pathological lymph node size in CT-imaging in patients with Hodgkin lymphoma and to evaluate its effect on staging, chemotherapy regimes and radiation field size. Materials and methods Pretherapeutic CT-scans of 10 consecutive patients with Hodgkin lymphoma have been evaluated based on two different definitions for malignant lymph node size; the classification of the German stu…

AdultMalePathologymedicine.medical_specialtyAdolescentLymph node regionsmedicine.medical_treatmentSensitivity and Specificity030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRisk FactorsMedicineHumansRadiology Nuclear Medicine and imagingLymph nodePathologicalAgedNeoplasm Stagingbusiness.industryRadiation fieldHematologyMiddle AgedCombined Modality TherapyHodgkin Disease3. Good healthRadiation therapymedicine.anatomical_structureOncology030220 oncology & carcinogenesisLymphatic MetastasisHodgkin lymphomaFemaleLymphRadiologyLymph NodesCt imagingbusinessTomography X-Ray ComputedRadiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
researchProduct

Interaction between strong radiation fields and two-level atoms: A canonical transformation approach

2008

PhysicsQuantum mechanicsRadiation fieldLaser probeQuantum electrodynamicsCanonical transformationRadiationUnitary transformation
researchProduct

Bell's inequality violation for entangled generalized Bernoulli states in two spatially separate cavities

2005

We consider the entanglement of orthogonal generalized Bernoulli states in two separate single-mode high-$Q$ cavities. The expectation values and the correlations of the electric field in the cavities are obtained. We then define, in each cavity, a dichotomic operator expressible in terms of the field states which can be, in principle, experimentally measured by a probe atom that ``reads'' the field. Using the quantum correlations of couples of these operators, we construct a Bell's inequality which is shown to be violated for a wide range of the degree of entanglement and which can be tested in a simple way. Thus the cavity fields directly show quantum non-local properties. A scheme is als…

PhysicsQuantum PhysicsBell stateField (physics)Cavity quantum electrodynamicsFOS: Physical sciencesQuantum entanglementSettore FIS/03 - Fisica Della MateriaAtomic and Molecular Physics and OpticsEntanglementBernoulli's principleOperator (computer programming)Cavity radiation fieldBell's theoremQuantum mechanicsBell's inequalityBernoulli processQuantum Physics (quant-ph)Quantum
researchProduct

EPR DOSIMETRY IN A MIXED NEUTRON AND GAMMA RADIATION FIELD

2004

Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident a…

inorganic chemicalsSafety ManagementMaterials scienceQuality Assurance Health CareRadiation DosageRisk AssessmentSensitivity and Specificitylaw.inventionRadiation Protectionstomatognathic systemlawNuclear ReactorsRisk FactorsmedicineDosimetryHumansRadiology Nuclear Medicine and imagingNeutronIrradiationElectron paramagnetic resonanceSpectroscopyRadiometryNeutronsObserver VariationRadiationRadiological and Ultrasound Technologybusiness.industryRadiochemistryPublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyReproducibility of ResultsGeneral MedicineReference StandardsTooth enamelEPR DOSIMETRY MIXED NEUTRON AND GAMMA RADIATION FIELDstomatognathic diseasesmedicine.anatomical_structureCriticalityGamma RaysAbsorbed doseBody BurdenFranceNuclear medicinebusinessRadioactive Hazard ReleaseRelative Biological Effectiveness
researchProduct

Potential scattering transitions in a strong chaotic non-Markovian radiation field.

1989

Theorie non relativiste de la diffusion par un potentiel en presence d'un champ laser intense, fluctuant en amplitude et en phase, a l'approximation de Born. Calcul des largeurs et profils de raies et des facteurs de coherence en fonction de l'intensite du laser

PhysicsScatteringRadiation fieldChaoticPhysics::Atomic PhysicsAtomic physicsExcitationLaser beamsPhysical review. A, General physics
researchProduct

THE EFFECT OF GADOLINIUM ON THE ESR RESPONSE OF ALANINE AND AMMONIUM TARTRATE EXPOSED TO THERMAL NEUTRONS

2008

Many efforts have been made to develop neutron capture therapy (NCT) for cancer treatment. Among the challenges in using NCT is the characterization of the features of the mixed radiation field and of its components. In this study, we examined the enhancement of the ESR response of pellets of alanine and ammonium tartrate with gadolinium oxide exposed to a thermal neutron beam. In particular, the ESR response of these dosimeters as a function of the gadolinium content inside the dosimeter was analyzed. We found that the addition of gadolinium improves the sensitivity of both alanine and ammonium tartrate. However, the use of gadolinium involves a reduces in or abolishes tissue equivalence b…

High atomic numberHot TemperatureGadoliniumBiophysicschemistry.chemical_elementGadoliniumRadiation DosageSensitivity and SpecificityRadiology Nuclear Medicine and imagingAmmonium tartrateRadiometryTartratesAlanineNeutronsRadiationDosimeterAlanineRadiation fieldRadiochemistryElectron Spin Resonance SpectroscopyReproducibility of ResultsDose-Response Relationship RadiationNeutron temperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Neutron capturechemistryESR dosimetry thermal neutronsNuclear chemistry
researchProduct

Modeling of an annular photocatalytic reactor for water purification: oxidation of pesticides.

2004

Photocatalytic oxidation (PCO) over titanium dioxide (TiO2) is a “green” sustainable process for the treatment and purification of water and wastewater. However, the application of PCO for wastewater treatment on an industrial scale is currently hindered by a lack of simple mathematical models that can be readily applied to reactor design. Current models are either too simplistic or too rigorous to be useful in photocatalytic reactor design, scale-up, and optimization. In this paper a simple mathematical model is presented for slurry, annular, photocatalytic reactors that still retains the essential elements of a rigorous approach while providing simple solutions. The model extends the appl…

LightPhotochemistrySettore ING-IND/25 - Impianti ChimiciPortable water purificationCatalysisCartesian coordinateWater Purificationchemistry.chemical_compoundRadiation fieldEnvironmental ChemistryScattering RadiationComputer SimulationPesticidesReactor designProcess engineeringTitaniumMethylurea CompoundsMathematical modelbusiness.industryPhenylurea CompoundsEnvironmental engineeringGeneral ChemistryModels TheoreticalSustainable processesSustainable processWastewaterchemistryTitanium dioxidePhotocatalysisSlurrySewage treatmentbusinessOxidation-ReductionEnvironmental sciencetechnology
researchProduct